Remember if your organisation receives an FSN from a manufacturer, always act on it. Medical Device Safety Officers (in England): ask the manufacturer to add you to their distribution list for field safety notices (FSNs). You should also report directly to manufacturers if your local or national systems do not.Īll medical, nursing and technical staff involved in the use and maintenance of these devices. Report adverse events involving these devices through your local incident reporting system and/or your national incident reporting authority as appropriate: England, Scotland, Northern Ireland, Wales.Contact Philips to order replacement batteries. Once installed, the device will indicate via an error message if battery replacement is necessary.Install the software update (version A.01.11) described in the F SN.Philips are developing a software update that will assist in battery management and will contact you once this is available. Ensure that systems are in place to routinely assess battery condition.If necessary, replace the battery in accordance with the instructions in the FSN. Check if the battery has exceeded 300 charge-discharge cycles or if the battery state of health is less than 80%.Identify all affected devices using the manufacturer's Field Safety Notices (FSNs) for the TC Cardiograph and the Efficia monitor.Ĭontact Philips to confirm receipt of each FSN using their response form. Key Features: Visual guidance to simplify ECGs Automated reporting sequence saves time Philips DXL ECG Algorithm expands diagnostic capabilities/li> Lead placement aids accurate placement of leads on the patient Saved ECGS can be quickly accessed Critical Value statements speed the delivery of urgent care Advanced bidirectional network communication for secure connection NOTE: Software and Installed Options Vary, PLEASE EMAIL WITH REQUIRMENTS BEFORE PURCHASE TO CONFIRM! Specifications: Main Application Revision Options: (PLEASE EMAIL REQUIREMENTS BEFORE PURCHASING TO ENSURE UNIT HAS OPTIONS AVAILABLE): D01: All Orders Support D02: ADT Support D03: Philips ECG Interpretative Algorithm D04: Pharma Support D05: Full Disclosure D06: ECG Archive Storage D07: Manual Order D12: Last ECG & Interactive Query D21/D22: Wireless LAN 802.11 D24/D25: SDIO Wireless 802.Manufactured by Philips – this problem affects lithium ion batteries that have exceeded their specified replacement interval or number of charging cycles. Philips PageWriter TC70 cardiograph is designed to simplify diagnostic ECG testing and streamline workflow – where an automated workflow and outstanding clinical support is critical. Description:Philips Pagewriter TC70 Cardiograph ECG/EKG Monitor w/ Stand The Philips Pagewriter TC70 Cardiograph ECG/EKG Monitor w/ Stand is versatile enough for use in both hospital and outpatient care settings, and for a variety of ECG testing. UNLESS OTHERWISE NOTED IN THE DESCRIPTION. THEY DO NOT COME WITH ANY CABLES, SENSORS, ACCESSORIES, ETC. COMPLETE UNITS ALL COME WITH A POWER CORD. IF THERE IS AN ERROR IN A LISTING, WE WILL DO OUR BEST TO RESOLVE ANY ISSUES TO THE BEST OF OUR ABILITIES THAT MAY ARISE BEFORE OR AFTER A SALE. Philips Pagewriter TC70 ECG/EKG Monitor w/ Cart * IMPORTANT - PLEASE READ BEFORE PURCHASING! * ALL PICTURES OF ITEMS BEING SOLD ARE USED FOR REFERENCE PURPOSES AND ARE DESCRIBED AS ACCURATELY AS POSSIBLE.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |